Mini Automatic Aerosol Fire Extinguishers
Mini Automatic Aerosol Fire Extinguisher is an intelligent fire extinguishing device, as it is compact in size, space-saving, and highly efficient in fire protection.
It features both thermal and manual operation capabilities, and is a standalone unit with an automatic detection mechanism, eliminating the need for separate detectors or release devices.
When the ambient temperature reaches the preset level, the thermal detection function of the mini aerosol device will automatically activate, releasing condensed aerosol to quickly extinguish the fire, making it the perfect fire protection solution.
aerosol fire extinguisher
Home » Aerosol Fire Extinguisher
Specifications and Technical Parameters
Model Specifications
Comment:D: Electrical Activation W: Thermal Activation C: Electromagnetic Activation
Model Specifications | Protected Volume (m³) | External Dimensions (mm) | Extinguishing Concentration | Activation Method | Shelf Life |
QRRO.01GW/S | 0.1 | 44*29*22 | 100g/m³ | W | 10 years |
QRR0.016G/S | 0.16 | 74*60*38 | 100g/m³ | W | 10 years |
QRRO.03GW/S | 0.3 | 135*90*20 | 100g/m³ | D、W、C | 10 years |
QRR0.05G/S | 0.5 | 152*125*28 | 100g/m³ | D、W、C | 10 years |
QRRO.08G/S | 0.8 | 152*125*28 | 100g/m³ | D、W、C | 10 years |
QRRO.1GW/S | 0.7 | Ф80X120 | 150g/m³ | D、W、C | 5 years |
QRRO.125GW/S | 1.25 | Ф100X132 | 100g/m³ | D、W、C | 10 years |
ORRO.15GW/S | 1 | Ф100X132 | 150g/m³ | D、W、C | 5 years |
ORRO.16GW/S | 1.6 | Ф100X133 | 100g/m³ | D、W、C | 10 years |
ORRO.20GW/S | 1.2 | Ф127X158 | 100g/m³ | D、W、C | 10 years |
QRRO.25GW/S | 1.7 | Ф127X158 | 150g/m³ | D、W、C | 5 years |
ORR0.26GW/S | 2.6 | Ф127X158 | 100g/m³ | D、W、C | 10 years |
QRR0.30GW/S | 3 | Ф127X158 | 100g/m³ | D、W、C | 10 years |
QRRO.5GW/S | 5 | Ф114X215 | 100g/m³ | D、W | 10 years |
ORRO.15G/S-JXJA | 2.14 | 255*68*46 | 70g/m³ | D、W | 10 years |
Technical Parameters
Working Environment Temperature Range | -40℃~+90℃ |
Relative Humidity | ≤95% |
Extinguishing Time | Within 30 seconds after the spray has ended |
Spray Time | ≤10S |
Spray Latency Time | ≤5S |
Activation Temperature | 170+10℃ |
System Activation Method | Thermal Fuse |
Multi-Unit Linkage Method | Series Connection |
Application Scenarios
Suitable for extinguishing the following fires:
- Construction Industry: High-rise buildings, industrial buildings’ transformer cabinets, safes in libraries, archives rooms, document rooms, and underground storage rooms.
- Communications Industry: Telecommunications rooms, computer rooms, communication base stations, relay stations, data processing rooms, remote control rooms, precision equipment distribution cabinets, and cabinets.
- Power Industry: Various high and low voltage transformer cabinets, control cabinets, distribution cabinets, and switchgear.
- Metallurgy Industry: Electronic instrument control cabinets, transformer cabinets.
- Petrochemical Industry: Transformer cabinets, control cabinets, distribution cabinets, switchgear.
- Transportation Industry: Locomotive control cabinets, railway power lines, aviation, and marine signal station control cabinets, transformer cabinets.
- Other Industries: CNC and other high-value machinery, equipment switch cabinets, distribution cabinets, control cabinets, etc.
Inappropriate Application Areas:
- Explosive hazard areas;
- Oxidizers such as nitrocellulose;
- Active metals such as potassium;
- Chemical fires that decompose on their own, such as hydrogen peroxide.
Product Advantages
- Environmentally friendly product with good cleanliness;
- High fire extinguishing efficiency, no residue; lightweight, easy to install;
- Focused protection, early fire extinguishing to reduce damage without pressure release;
- Leak-proof, almost zero maintenance cost;
- Convenient design, widely adaptable.
Precautions
- Before installing the small gas aerosol series fire extinguishing device, read the manual carefully and consult our technical staff for any questions.
- The installation and commissioning of the small gas aerosol series fire extinguishing device must be carried out by professionally trained personnel, and should not be moved arbitrarily after installation.
- In case of fire, on-site personnel must evacuate immediately and close doors and windows if possible.
- After discharge, if it is necessary to remove it in a short time, wear heat-resistant gloves to avoid burns.
- The small gas aerosol series fire extinguishing device should not be disassembled within or beyond the validity period to prevent accidents. After the validity period, the user should contact the supplier for replacement and recycling.
- When installed inside a high-voltage cabinet, the small gas aerosol series fire extinguishing device should meet the safety distance from the live parts inside the cabinet. The power supply inside the cabinet must be turned off during installation to ensure the safety of the device wiring.
- During transportation, protect against rain and moisture, handle with care.
- Storage should be in a ventilated and dry warehouse.