Home » Dual-Cylinder FM200 Cabinet Fire Suppression System
Dual Cylinder FM200 Fire Suppression System
The Flarenix Dual-Cylinder FM200 Cabinet Fire Suppression System is a high-reliability fire protection solution designed for mission-critical environments where redundancy and continuous fire suppression capability are essential. Unlike traditional single-cylinder FM200 systems, this Clean Agent Fire Suppression System houses two independent, synchronized FM200 storage cylinders, providing backup activation, failover protection, and multi-zone coverage.
With capacities ranging from 40L × 2 to 180L × 2 (10.6 gal × 2 to 47.5 gal × 2) and a discharge time of ≤10 seconds, it meets the stringent requirements of data centers, telecom hubs, industrial automation rooms, and financial IT infrastructures. Fully UL/FM-certified and compliant with NFPA 2001, this system ensures precise agent discharge, pressure balance, and long-term operational reliability.
Key Features
- Dual-Cylinder Redundancy & Backup Activation – Independently stored FM200 agent ensures instant reactivation in case of a recurring fire, preventing downtime.
- Balanced Discharge for Maximum Suppression Efficiency – The synchronized dual-cylinder system prevents pressure inconsistencies, ensuring uniform agent distribution.
- Compact, Piping-Free Installation – Eliminates the need for external piping, making it ideal for facilities with strict space constraints.
- Fast & Residue-Free Suppression – Releases FM200 within ≤10 seconds, ensuring non-conductive, non-corrosive protection for sensitive equipment.
- Advanced Safety Monitoring & Compliance – Features built-in pressure sensors, leak detection, and automatic diagnostic reporting, ensuring full NFPA 2001 and UL/FM compliance.
- Manual & Automatic Operation for Flexible Deployment – Supports integrated alarm activation, automatic release, or manual override, providing operational adaptability.
- Long-Term Reliability & Low Maintenance Costs – Standard NFPA inspections ensure an estimated service life exceeding 10 years, reducing long-term ownership costs.
Technical Specifications
Model | Storage Capacity (L / gal per cylinder) | Cabinet Dimensions (L × W × H mm / in) |
FN40x2/2.5 | 40 × 2 (10.6 × 2 gal) | 1040 × 430 × 1200 mm (41″ × 17″ × 47″) |
FN70x2/2.5 | 70 × 2 (18.5 × 2 gal) | 1040 × 430 × 1400 mm (41″ × 17″ × 55″) |
FN90x2/2.5 | 90 × 2 (23.8 × 2 gal) | 1040 × 430 × 1700 mm (41″ × 17″ × 67″) |
FN100x2/2.5 | 100 × 2 (26.4 × 2 gal) | 1040 × 430 × 1700 mm (41″ × 17″ × 67″) |
FN120x2/2.5 | 120 × 2 (31.7 × 2 gal) | 1040 × 430 × 1900 mm (41″ × 17″ × 75″) |
FN150x2/2.5 | 150 × 2 (39.6 × 2 gal) | 1100 × 500 × 1900 mm (43″ × 20″ × 75″) |
FN180x2/2.5 | 180 × 2 (47.5 × 2 gal) | 1105 × 500 × 2100 mm (43″ × 20″ × 83″) |
Technical Specification | Value (Metric / Imperial) |
FM200 Agent Fill Density | <1120 kg/m³ (69.9 lb/ft³) |
Storage Pressure at 20°C (68°F) | 2.5 MPa (362.5 psi) |
Maximum Working Pressure | 4.2 MPa (609 psi) |
Discharge Time | <10 sec |
Operating Voltage/Current | DC 24V / 1.2A |
Suppression Method | Total Flooding |
Application
The Flarenix Dual-Cylinder FM200 Cabinet System is tailored for specialized environments requiring redundant suppression, multi-zone protection, or rapid system reset capabilities.
High-Reliability IT & Data Infrastructure
Modern data centers and IT facilities demand continuous fire suppression without service disruptions. A single-cylinder system may not provide immediate reactivation, leaving critical IT assets vulnerable.
The dual-cylinder FM200 system ensures instant backup activation, allowing seamless re-protection after a fire event. Designed for edge data centers, high-density server rooms, and cloud computing facilities, it prevents fire reignition while preserving IT uptime.
Multi-Zone Fire Suppression in Electrical & Industrial Facilities
Large industrial sites often require fire suppression across multiple electrical enclosures or switchgear cabinets, making a single-point system ineffective.
The Flarenix Dual-Cylinder FM200 System provides independent cylinder activation, allowing flexible fire suppression in separate areas or staggered sequences. It is an ideal solution for SCADA-controlled power grids, energy substations, and multi-compartment automation hubs.
Facilities Requiring Immediate System Reset & Reuse
Financial institutions, telecom switching hubs, and pharmaceutical R&D labs cannot afford downtime caused by a discharged fire suppression system. Traditional systems require recharging before reuse, leading to potential safety gaps.
This dual-cylinder system enables continuous fire protection by keeping one cylinder pressurized while the other discharges, ensuring fail-safe suppression for high-security banking, 5G network hubs, and biotechnology laboratories.
High-Security & Regulatory-Compliant Environments
Government buildings, defense command centers, and classified research labs require redundant, failsafe fire suppression that meets strict UL/FM/NFPA regulations.
The Flarenix Dual-Cylinder FM200 System ensures full NFPA 2001 compliance, featuring UL-listed cylinder valves, FM-approved nozzles, and automated performance diagnostics. This makes it the preferred choice for high-security institutions requiring uninterrupted fire protection.
Custom Solutions
The Flarenix Dual-Cylinder FM200 Fire Suppression System is engineered for maximum reliability, ensuring instant fire suppression backup, enhanced safety monitoring, and compliance with U.S. fire safety standards.
- Dual-cylinder redundancy prevents re-ignition risks and minimizes downtime.
- No external piping required, reducing installation complexity.
- Complies with NFPA 2001, UL, and FM standards for regulatory approval.
- Low maintenance costs with estimated 10+ year service life.
Contact us today to integrate this high-performance fire suppression system into your facility.