IG-541 inergen fire suppression system
The certification of Flarenix

IG-541
Fire Suppression System

The Flarenix IG 541 Fire Suppression System is a high-performance, environmentally friendly inert clean agent fire suppression system, designed for critical infrastructure and mission-critical applications. Composed of 52% nitrogen, 40% argon, and 8% carbon dioxide, this natural, non-toxic, and residue-free extinguishing agent provides effective fire suppression while ensuring safety for occupied spaces.

The IG 541 fire suppression system works by reducing the oxygen concentration in the protected space to a level that prevents combustion while remaining safe for human occupants. Unlike CO₂-based suppression systems, IG 541 allows personnel to remain in the area without the risk of asphyxiation. Additionally, compared to synthetic agents like FM200 or Novec 1230, IG 541 is naturally occurring, making it cost-effective, environmentally sustainable, and free from chemical regulatory restrictions.

With a working pressure of 15 MPa (2175 psi) and discharge design concentrations of up to 43.9%, the system ensures rapid, uniform suppression across enclosures, making it ideal for total flooding applications. The Flarenix IG 541 system meets NFPA 2001, UL, and FM standards, ensuring reliable fire protection for high-risk environments.

Key Features

  • 100% Natural Inert Gas Fire Suppression – A non-toxic, eco-friendly gas blend (N₂, Ar, CO₂), safe for occupied spaces.
  • Residue-Free, No Cleanup Required – Unlike chemical agents, IG 541 leaves no residue, making it ideal for sensitive electronics, clean rooms, and data centers.
  • Designed for Total Flooding Applications – Suppresses fires by reducing the oxygen concentration below combustion levels without posing a risk to occupants.
  • Optimized for Large & Multi-Zone Protection – The system’s high-pressure storage (15 MPa) allows for long pipe runs, ensuring uniform suppression across extensive facilities.
  • Highly Intelligent & Configurable – Supports independent or distributed system configurations, providing flexible protection for single or multiple enclosures.
  • Meets NFPA 2001, UL, & FM Certification Standards – Compliant with global fire safety regulations, ensuring reliable performance in regulated industries.
  • Flexible Activation Methods – Supports automatic, manual, and emergency mechanical activation, ensuring rapid response to fire events.
  • Cost-Effective & Low Maintenance – IG 541 has an unlimited shelf life, no chemical breakdown, and requires minimal ongoing maintenance compared to FM-200 or Novec 1230.
An independent system for real-time response to fire detection

Technical Specifications

Technical Parameter80L Model (QMH15/80-FN)90L Model (QMH15/90-FN)Imperial Units
Design Pressure17.2 MPa17.2 MPa2495 psi
Working Pressure15 MPa15 MPa2175 psi
Operating Temperature Range0°C to +50°C0°C to +50°C32°F to 122°F
Cylinder Volume80L90L21.1 gal / 23.8 gal
Cylinder Outer DiameterØ279 mmØ279 mm / Ø325 mmØ10.98 in / Ø12.80 in
Cylinder Height1578 ± 73 mm1345 ± 60 mm62.1 ± 2.87 in / 52.9 ± 2.36 in
IG 541 Gas Fill Volume12 m³13.5 m³424.8 ft³ / 478.5 ft³
Cylinder Valve Nominal SizeDN15DN150.59 in (Nominal)
Cylinder Valve Outlet ThreadM30 × 1.5M30 × 1.5Metric
Safety Relief Pressure23 MPa ± 1.15 MPa23 MPa ± 1.15 MPa3335 psi ± 167 psi
Fire Suppression Design Concentration (Class A)36.50%36.50%
Fire Suppression Design Concentration (Class B)43.90%43.90%

Why Choose IG 541 Over Other Fire Suppression Agents?

FeatureIG 541 (N₂, Ar, CO₂ Blend)CO₂FM-200 / Novec 1230
Occupancy SafetySafe for occupied spacesRequires evacuationSafe for occupied spaces
Environmental Impact100% natural, no restrictionsNo ozone depletion, but requires safety measuresSynthetic, subject to environmental regulations
Discharge ResidueNone (clean agent)NoneNone (clean agent)
Storage Pressure15 MPa (2175 psi)5.7 MPa (827 psi)4.2 MPa (609 psi)
Discharge Time60 seconds30-60 seconds10 seconds
Refill AvailabilityReadily available (natural gases)Readily availableLimited supply, higher cost
Longevity & MaintenanceNo chemical degradationNo degradationRequires chemical monitoring
IG-541 inergen fire suppression system

Application

The IG 541 fire suppression system is designed for fire protection in high-value, mission-critical environments, offering safe, clean, and effective suppression.

Data Centers & IT Facilities

Protects server rooms, network infrastructure, and IT control centers, ensuring non-conductive fire suppression without damage to sensitive electronic equipment.

Provides fire suppression for transformer rooms, generator enclosures, and control centers, ensuring fast and uniform agent discharge for mission-critical infrastructure.

Ensures fire protection for historical artifacts, valuable documents, and irreplaceable records, offering total flooding protection without chemical contamination.

Secures broadcast equipment, signal relay rooms, and telecom facilities, preventing fire-related service disruptions with residue-free suppression.

Custom Solutions

The IG 541 fire suppression system is a highly advanced, environmentally safe inert gas solution, offering effective, residue-free fire protection for mission-critical industries.

  • 100% natural, sustainable, and eco-friendly
  • Safe for occupied spaces, with no chemical residue or cleanup
  • Complies with NFPA 2001, UL, and FM fire suppression standards
  • Engineered for total flooding and multi-zone fire protection
  • Cost-effective, with long-term reliability and minimal maintenance

Contact us today to integrate this high-performance IG 541 fire suppression system into your facility.